Wang, Yifei and Ma, Xiandong and Joyce, Malcolm John (2016) Reducing sensor complexity for monitoring wind turbine performance using principal component analysis. Renewable Energy, 97. 444–456. ISSN 0960-1481
DG_system_condition_monitoring_paper_Lancaster_University_final.pdf - Accepted Version
Available under License Creative Commons Attribution-NonCommercial-NoDerivs.
Download (1MB)
Abstract
Availability and reliability are among the priority concerns for deployment of distributed generation (DG) systems, particularly when operating in a harsh environment. Condition monitoring (CM) can meet the requirement but has been challenged by large amounts of data needing to be processed in real time due to the large number of sensors being deployed. This paper proposes an optimal sensor selection method based on principal component analysis (PCA) for condition monitoring of a DG system oriented to wind turbines. The research was motivated by the fact that salient patterns in multivariable datasets can be extracted by PCA in order to identify monitoring parameters that contribute the most to the system variation. The proposed method is able to correlate the particular principal component to the corresponding monitoring variable, and hence facilitate the right sensor selection for the first time for the condition monitoring of wind turbines. The algorithms are examined with simulation data from PSCAD/EMTDC and SCADA data from an operational wind farm in the time, frequency, and instantaneous frequency domains. The results have shown that the proposed technique can reduce the number of monitoring variables whilst still maintaining sufficient information to detect the faults and hence assess the system’s conditions.