Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons

UNSPECIFIED (2010) Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons. European Physical Journal C: Particles and Fields, 70 (3). pp. 755-785. ISSN 1434-6044

Full text not available from this repository.

Abstract

The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.8% in the endcaps. This leads to an estimated contribution to the constant term of (0.29(-0.04)(+0.05))% in the barrel and (0.54(-0.04)(+0.06))% in the endcaps. The same data are used to measure the drift velocity of ionization electrons in liquid argon, which is found to be 4.61 +/- 0.07 mm/mu s at 88.5 K and 1 kV/mm.

Item Type:
Journal Article
Journal or Publication Title:
European Physical Journal C: Particles and Fields
Uncontrolled Keywords:
/dk/atira/pure/subjectarea/asjc/3100/3101
Subjects:
?? physics and astronomy (miscellaneous)engineering (miscellaneous)qc physics ??
ID Code:
67788
Deposited By:
Deposited On:
29 Nov 2013 11:43
Refereed?:
Yes
Published?:
Published