Franchini, P. and Nowak, J. (2025) Production, Quality Assurance and Quality Control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber. European Physical Journal C: Particles and Fields. ISSN 1434-6044 (In Press)
2507.07226v1.pdf - Accepted Version
Available under License Creative Commons Attribution.
Download (21MB)
Abstract
The DarkSide-20k dark matter direct detection experiment will employ a 21 m^2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. 16 Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the quality assurance and quality control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision flip-chip bonding, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.
Altmetric
Altmetric