Gamage, Kelum and Joyce, Malcolm and Taylor, Graeme (2012) A digital approach to neutron-gamma imaging with a narrow tungsten collimator aperture and a fast organic liquid scintillator detector. Applied Radiation and Isotopes, 70 (7). pp. 1223-1227. ISSN 0969-8043
Full text not available from this repository.Abstract
A digital neutron–γ imaging technique for mixed radiation field is described. The imaging system is based upon an organic liquid scintillator detector, a narrow tungsten collimator, fast digitiser and adjustable equatorial mount. Radioactive sources have been attached to a vertical plane and the digitiser has been used to digitise neutron and γ events. The digitised events have been discriminated using pulse gradient analysis and images have been generated of the count distribution in the source plane.