Digital approaches to field neutron spectrometry-NPL Report IR 23.

Akurugoda Gamage, Kelum Asanga and Hawkes, Nigel and Taylor, Graeme (2010) Digital approaches to field neutron spectrometry-NPL Report IR 23. Working Paper. National Physical Laboratory.

Full text not available from this repository.

Abstract

Miniature digitizing electronics have been coupled to a detector based on an organic liquid scintillator to form a digital neutron and gamma spectrometer. The digitizing electronics are physically small enough to be packaged with a detector to form an easily portable unit. The spectrometer was exposed to a selection of the wellcharacterised radiation fields available at NPL, and the performance of three different neutron / gamma discrimination algorithms were compared. The energy resolution of the system was also assessed. Conclusions are presented on the best algorithm to use in such a system, and on the performance and ease of use of the spectrometer in comparison with conventional analogue systems.

Item Type:
Monograph (Working Paper)
Uncontrolled Keywords:
/dk/atira/pure/core/keywords/engineering
Subjects:
?? engineeringtk electrical engineering. electronics nuclear engineering ??
ID Code:
39977
Deposited On:
24 Mar 2011 14:33
Refereed?:
No
Published?:
Published
Last Modified:
15 Jul 2024 07:49