Handheld dynamometry : Validity and reliability of measuring hip joint rate of torque development and peak torque

McNabb, Katherine and Sánchez, María B. and Selfe, James and Reeves, Neil D. and Callaghan, Michael (2024) Handheld dynamometry : Validity and reliability of measuring hip joint rate of torque development and peak torque. PLoS One, 19 (8): e0308956. ISSN 1932-6203

Full text not available from this repository.

Abstract

Introduction: Measuring rate of torque development (RTD) and peak torque (PT) for hip muscle performance presents challenges in clinical practice. This study investigated the construct validity of a handheld dynamometer (HHD) versus an isokinetic dynamometer (IKD), and intra-rater repeated reliability for RTD and PT and their relationship in hip joint movements. Methods: Thirty healthy individuals (mean age = 30 ± 8 years, 13 males) underwent two test sessions in a single day. RTD (0–50, 0–100, 0–150, 0-200ms) and PT normalised to body mass in maximal voluntary isometric contractions were measured using a HHD and an IKD in hip flexion, extension, abduction, adduction, internal and external rotation. Results: For validity between the devices, RTD0-50 exhibited the largest significant systematic bias in all hip movements (3.41–11.99 Nm·s-1 kg-1) and widest limits-of-agreement, while RTD0-200 had the lowest bias (-1.33–3.99 Nm·s-1 kg-1) and narrowest limits-of-agreement. For PT, agreement between dynamometers was observed for hip flexion (0.08 Nm·kg-1), abduction (-0.09 Nm·kg-1), internal (-0.01 Nm·kg-1), and external rotation (0.05 Nm·kg-1). For reliability, intra-rater intraclass correlation coefficient (ICC2,1) ranged from moderate to good in RTD0-50 and RTD0-100 (0.5–0.88), and good to excellent in RTD0-150 and RTD0-200 (0.87–0.95) in all movements. The HHD displayed excellent intra-rater, relative reliability values (ICC2,1) in all movements (0.85–0.95). Pearson’s correlation revealed good linear correlation between PT and RTD0-150 and RTD0-200 in all movements (r = .7 to .87, p = < .001). Conclusion: Validity analysis demonstrated significant systematic bias and lack of agreement in RTD measures between the HHD and IKD. However, the HHD displays excellent to moderate intra-rater, relative reliability for RTD and PT measures in hip movements. Clinicians may use the HHD for hip muscle PT assessment but note, late phase RTD measures are more reliable, valid, and relate to PT than early phase RTD. Additionally, the correlation between RTD and PT at various time epochs was examined to better understand the relationship between these measures.

Item Type:
Journal Article
Journal or Publication Title:
PLoS One
Uncontrolled Keywords:
/dk/atira/pure/subjectarea/asjc/1100
Subjects:
?? agricultural and biological sciences(all)biochemistry, genetics and molecular biology(all)medicine(all) ??
ID Code:
223244
Deposited By:
Deposited On:
19 Aug 2024 09:20
Refereed?:
Yes
Published?:
Published
Last Modified:
27 Nov 2024 02:04