Experimental investigation on the failure modes of grouted sleeve connections under thermal and mechanical loads

Wang, T. and Xu, H. and Yu, M. and Xu, L. and Ye, J. (2020) Experimental investigation on the failure modes of grouted sleeve connections under thermal and mechanical loads. Engineering Failure Analysis, 109: 104246.

[thumbnail of Grouted_Sleeves_11_11.1]
Text (Grouted_Sleeves_11_11.1)
Grouted_Sleeves_11_11.1.pdf - Accepted Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (1MB)

Abstract

Grouted sleeve connections are widely used in precast concrete structures for joining rebar. In order to understand the behavior of grouted sleeves under and after fire, tensile tests are carried out on grouted sleeves with threaded bars under three different thermo-mechanical loading conditions, i.e., loading when temperature is constant, heating when a constant mechanical load is maintained and loading at room temperature on previously heated sleeves. Tensile tests of continuous rebar are also conducted for comparisons. Failure modes and degradation of mechanical properties of both grouted sleeve connections and continuous rebar subjected to above conditions are studied. It is found that the temperature resistances of the grouted sleeve connections with or without considering heating process are significantly different, while such differences are negligible for continuous rebar. It is also found that grouted sleeve connections can restore some of the mechanical capacities after they are cooled down to the room temperature. Finally, predictive models are proposed for potential adoption in fire resistance design and post fire evaluation of grouted sleeve connections.

Item Type:
Journal Article
Journal or Publication Title:
Engineering Failure Analysis
Additional Information:
This is the author’s version of a work that was accepted for publication in Engineering Failure Analysis. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Engineering Failure Analysis, 109, 2020 DOI: 10.1016/j.engfailanal.2019.104246
Subjects:
?? grouted sleeves connectiontemperature-load pathsfailure modetensile behaviorcalculation method ??
ID Code:
139725
Deposited By:
Deposited On:
05 Feb 2020 09:05
Refereed?:
Yes
Published?:
Published
Last Modified: