Accuracy of the Diffusive Gradients in Thin-Films Technique: Diffusive Boundary Layer and Effective Sampling Area Considerations

Warnken, Kent W. and Zhang, Hao and Davison, William (2006) Accuracy of the Diffusive Gradients in Thin-Films Technique: Diffusive Boundary Layer and Effective Sampling Area Considerations. Analytical Chemistry, 78 (11). pp. 3780-3787. ISSN 0003-2700

Full text not available from this repository.

Abstract

When using the diffusive gradients in thin-films (DGT) technique in well-stirred solutions, the diffusive boundary layer has generally been ignored on the assumption that it is negligibly thin compared to the total thickness of g, i.e., the sum of the thickness of the prefilter and diffusive gel. Deployment of devices with different diffusive layer thicknesses showed that the thickness of the DBL was ~0.23 mm in moderate to well-stirred solutions, but substantially thicker in poorly or unstirred solutions. Measurement of the distribution of Cd in the DGT resin gel at high spatial resolution (100 m) using laser ablation inductively coupled plasma mass spectrometry showed that the effective sampling window had a larger diameter (2.20 cm) than the geometric diameter of the exposure window (2.00 cm). Lateral diffusion in the gel, which had previously been neglected, therefore increased the effective surface area of the device by ~20%. The concentrations measured by DGT agreed well with the known concentrations in standard solutions for all diffusion layer thicknesses, when the effective area and the appropriate diffusive boundary layer (DBL) were used. The extent of the error associated with neglecting the DBL and using the geometric window area depends on the gel layer thickness and the true thickness of the DBL, as determined by the deployment geometry and flow regime. When DGT measurements were made in well-stirred solutions using a 0.80-mm diffusive gel, the effect of neglecting the DBL and using the inappropriate geometric area offset each other, with the error being <±10%. For precise measurements, and especially work involving speciation or kinetic measurements, where DGT devices with different diffusive gel layer thicknesses are deployed, it is necessary to use the effective area and the appropriate DBL thickness in the full DGT equation, which allows for the use of layer-specific diffusion coefficients

Item Type:
Journal Article
Journal or Publication Title:
Analytical Chemistry
Uncontrolled Keywords:
/dk/atira/pure/researchoutput/libraryofcongress/ge
Subjects:
?? ANALYTICAL CHEMISTRYGE ENVIRONMENTAL SCIENCES ??
ID Code:
9235
Deposited By:
Deposited On:
30 May 2008 15:53
Refereed?:
Yes
Published?:
Published
Last Modified:
16 Sep 2023 00:30