Abstract

A detailed experimental study has been made of suspected multipactor discharge in a klystron input cavity in the presence of an axial magneticfield.. The existence of the discharge was detected by changes in the return loss at the input coupler. This method does not require any modification of the cavity. Discharges appeared to take place over a range of input powers from 5 W up to 100 W for two distinct ranges of the magnetic field. Tests with a hand-heldpermanent magnet suggested that the discharges are located around the equator of the cavity. Comparison with theory confirmed that the lower band is probably a single-surface crossed-field multipactor discharge. Investigation of the upper band is continuing.

Item Type: Conference or Workshop Item (Other)
Journal or Publication Title: 2006 IEEE International Vacuum Electronics Conference held jointly with 2006 IEEE International Vacuum Electron Sources
Additional Information: 7th IEEE International Vacuum Electronics Conference (IVEC)/6th IEEE International Vacuum Electron Sources Conference (IVESC), Monterey, CA, APR 25-27, 2006
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Departments: Faculty of Science and Technology > Mathematics and Statistics
Faculty of Science and Technology > Engineering
ID Code: 26817
Deposited By: Prof Richard G. Carter
Deposited On: 27 Jul 2009 12:16
Refereed?: No
Published?: Published
Last Modified: 24 Jan 2014 06:12
Identification Number:
URI: http://eprints.lancs.ac.uk/id/eprint/26817

Actions (login required)

View Item