Chilingarov, Alexandre and Campbell, Duncan and Hughes, Gareth (2006) Interstrip capacitance stabilization at low humidity. Nuclear Instruments and Methods A, 560 (1). pp. 118-121. ISSN 0168-9002
Full text not available from this repository.Abstract
A long-term stabilisation of the interstrip capacitance after bias application is investigated with emphasis on low ambient humidity conditions. The measurements are made with ATLAS SCT microstrip detectors produced by Hamamatsu. It is shown that after the application of 150 V bias the interstrip capacitance is higher by 25–30% than its stable value. It is demonstrated that at low absolute humidity, mandatory for the SCT operation at subzero temperatures, the stabilisation time may be of order of months. Since the interstrip capacitance is one of the major sources of front-end electronics noise the results are important for the optimisation of operating conditions for the ATLAS SCT.
| Item Type: | Article |
|---|---|
| Journal or Publication Title: | Nuclear Instruments and Methods A |
| Uncontrolled Keywords: | Silicon microstrip detectors ; Interstrip capacitance |
| Subjects: | Q Science > QC Physics |
| Departments: | Faculty of Science and Technology > Physics |
| ID Code: | 19863 |
| Deposited By: | Dr Alexandre Chilingarov |
| Deposited On: | 17 Nov 2008 13:36 |
| Refereed?: | Yes |
| Published?: | Published |
| Last Modified: | 26 Jul 2012 15:35 |
| Identification Number: | |
| URI: | http://eprints.lancs.ac.uk/id/eprint/19863 |
Actions (login required)
| View Item |